Installation
Wiring
Connect the wires from the reader to the door controller according to the table.
AXIS A4020-E AXIS A4120-E | AXIS A1001 | Other Axis door controllers |
B | A | B |
A | B | A |
+ | 12 V | 12 V |
- | - | - |
Configure your device
The device works as a standard OSDP reader out-of-the-box. You can access specific features and change settings in AXIS Camera Station Secure Entry. Below is an example of how to configure the device through AXIS Camera Station Secure Entry.
Encrypted communication
OSDP Secure Channel
AXIS Camera Station Secure Entry supports OSDP (Open Supervised Device Protocol) Secure Channel to active line encryption between controller and Axis readers.
To turn on OSDP Secure Channel for an entire system:
Go to Configuration > Access control > Encrypted communication.
Enter your main encryption key and click OK.
Turn on OSDP Secure Channel. This option is only available after you enter the main encryption key.
By default, the main encryption key generates a OSDP Secure Channel key. To manually set the OSDP Secure Channel key:
Under OSDP Secure Channel, click .
Clear Use main encryption key to generate OSDP Secure Channel key.
Enter the OSDP Secure Channel key and click OK.
To turn on or turn off OSDP Secure Channel for a specific reader, see Doors and zones.
Specifications
Product overview
Reader indicator stripe
Behavior | State |
Flashing red | Waiting for controller connection |
DIP switches
DIP switch | Default setting | Function |
1 | Off | OSDP address: Off + Off = 0* Off + On = 1 On + Off = 2 On + On = 3 |
2 | Off | |
3 | Off | RS485 termination, Off = active |
4 | Off | Visually impaired mode** |
5 | Off | Keypad backlight, On = always on, Off = controlled by OSDP |
6 | Off | Secure mode*** |
* When switch 1 and 2 are both set to Off, you can use the command osdp_COMSET to change the address.** Visually impaired mode adds a delay before a key press is registered. Turn on visually impaired mode only if AXIS TA4401 Braille Label is installed on the device. *** When secure mode is turned on, the reader doesn’t allow unencrypted communication. See Encrypted communication. |
Buttons
Control button
- The control button is used for:
Resetting the product to factory default settings. See Reset to factory default settings.
Baud rate
The default baud rate is 9600. To change it, use the command osdp_COMSET
.
Troubleshooting
Reset to factory default settings
A reset to factory default resets all settings to the factory default values.
Remove the device from the backplate. This disconnects power from the device.
Remove the connector from the backplate.
Use a blunt instrument to press and hold the control button while you reconnect power by connecting the terminal block to the pins in the device. See Product overview. You will hear a short beep when you reconnect power. It indicates that the control button is pressed.
Keep the control button pressed for a few seconds.
Release the control button. You will hear a beep that indicates that the device has been reset to the factory default settings.
Put the terminal block in its place in the backplate.
Hook the device onto the backplate and close the unit slowly.